Woods-powr-grip MT5HV11DC Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Guincho Woods-powr-grip MT5HV11DC. Wood’s Powr-Grip MT5HV11DC User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 30
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
KEEP FOR FUTURE REFERENCE
INSTRUCTIONS
International Version
MODEL NUMBER: MT5HV11DC
SERIAL NUMBER: ___________
(please see serial label and record number here)
MANUAL TILTER
DC-VOLTAGE, 1-SCFM
READ ALL INSTRUCTIONS AND WARNINGS
BEFORE OPERATING THIS LIFTER
DESIGNED FOR THE MATERIALS HANDLING PROFESSIONAL
P.O. Box 368 908 West Main
Laurel, MT USA 59044
phone 800-548-7341
phone 406-628-8231
fax 406-628-8354
Vista de página 0
1 2 3 4 5 6 ... 29 30

Resumo do Conteúdo

Página 1 - INSTRUCTIONS

KEEP FOR FUTURE REFERENCE INSTRUCTIONS International Version MODEL NUMBER: MT5HV11DC SERIAL NUMBER: ___________ (please see serial label and rec

Página 2

Rev 7.0/12-12 8 MT5HV11DC: #35087 OPERATION BEFORE USING THE LIFTER The operator must determine whether the lifter is capable of performing each in

Página 3 - SPECIFICATIONS

Rev 7.0/12-12 9 MT5HV11DC: #35087 TO APPLY THE PADS TO A LOAD Positioning the Lifter on the Load Make certain that the contact surfaces of the load

Página 4 - WARNINGS

Rev 7.0/12-12 10 MT5HV11DC: #35087 Reading the Vacuum Gauge The vacuum gauge indicates the current vacuum level in the lifter’s vacuum system. The

Página 5 - OPERATING FEATURES

Rev 7.0/12-12 11 MT5HV11DC: #35087 TO LIFT AND MOVE THE LOAD Load Capacity and the Warning Light The lifter's Load Capacity is rated at a vacuu

Página 6 - ASSEMBLY

Rev 7.0/12-12 12 MT5HV11DC: #35087 In Case of Power Failure The vacuum package is equipped with a vacuum reserve tank, designed to maintain vacuum t

Página 7 - CHEDULE

Rev 7.0/12-12 13 MT5HV11DC: #35087 TO RELEASE THE PADS FROM THE LOAD WARNING: Load must be fully supported before releasing vacuum pads. When the l

Página 8 - INTENDED USE

Rev 7.0/12-12 14 MT5HV11DC: #35087 AFTER USING THE LIFTER Turn off the remote vacuum package by pushing the vacuum package valve handle inward to th

Página 9 - DISPOSAL OF THE LIFTER

Rev 7.0/12-12 15 MT5HV11DC: #35087 MAINTENANCE WARNING: Always make sure battery is disconnected before servicing lifter. INSPECTION SCHEDULE Perf

Página 10 - OPERATION

Rev 7.0/12-12 16 MT5HV11DC: #35087 If any deficiency is detected during the inspection, correct it before using the lifter. If necessary, return th

Página 11 - TO APPLY THE PADS TO A LOAD

Rev 7.0/12-12 17 MT5HV11DC: #35087 BATTERY TEST The lifter is equipped with a battery gauge to help the operator evaluate whether the battery has ad

Página 13 - TO LIFT AND MOVE THE LOAD

Rev 7.0/12-12 18 MT5HV11DC: #35087 battery is fully charged. Following long-term use, a battery gradually loses capacity. Replace it whenever the

Página 14 - TO TILT THE LOAD

Rev 7.0/12-12 19 MT5HV11DC: #35087 Cleaning Regularly clean the face of each vacuum pad to remove oil, dust and any other contaminates. Acceptable

Página 15 - Releasing the pads remotely

Rev 7.0/12-12 20 MT5HV11DC: #35087 VACUUM TEST Test the vacuum system for leakage routinely, as directed in the preceding INSPECTION and TESTING SCH

Página 16 - AFTER USING THE LIFTER

Rev 7.0/12-12 21 MT5HV11DC: #35087 AIR FILTER MAINTENANCE (for 1 oz [30 ml] bowl size filters) Filter Function and Conditions Requiring Service An a

Página 17 - MAINTENANCE

Rev 7.0/12-12 22 MT5HV11DC: #35087 AIR FILTER MAINTENANCE (for 4.4 oz [130 ml] bowl size filters) Filter Function and Conditions Requiring Service A

Página 18 - MAINTENANCE SCHEDULE

Rev 7.0/12-12 23 MT5HV11DC: #35087 VACUUM PUMP MAINTENANCE − DYNAFLO DV1032102 WARNING: Before proceeding with any maintenance, disconnect power so

Página 19 - BATTERY RECHARGE

Rev 7.0/12-12 24 MT5HV11DC: #35087 VACUUM PUMP MAINTENANCE − THOMAS 107CDC20 WARNING: Before proceeding with any maintenance, disconnect power sour

Página 20 - VACUUM PAD MAINTENANCE

Rev 7.0/12-12 25 MT5HV11DC: #35087 VACUUM SWITCH ADJUSTMENT Vacuum Switch Function18 A vacuum switch controls the low vacuum warning light and the v

Página 21 - Cleaning

Rev 7.0/12-12 26 MT5HV11DC: #35087 Adjustment Procedure WARNING: Lifting capacity decreases whenever vacuum switch is adjusted to maintain lower va

Página 22 - VACUUM TEST

Rev 7.0/12-12 27 MT5HV11DC: #35087 REPLACEMENT PARTS LIST Stock No. Description Qty. 93220 Vacuum Pump - Diaphragm Type - 1-SCFM [28 liters/minute]

Página 23 - AIR FILTER MAINTENANCE

Rev 7.0/12-12 1 MT5HV11DC: #35087 SPECIFICATIONS Model Number: MT5HV11DC Description: Designed for use with a crane or other hoisting equipment, th

Página 24

Rev 7.0/12-12 28 MT5HV11DC: #35087 LIMITED WARRANTY Powr-Grip products are carefully constructed, thoroughly inspected at various stages of product

Página 25 - Replacing the Head Assembly

Rev 7.0/12-12 2 MT5HV11DC: #35087 WARNINGS Powr-Grip is pleased to offer the most reliable vacuum lifters available. Despite the high degree of se

Página 26

Rev 7.0/12-12 3 MT5HV11DC: #35087 OPERATING FEATURES Note: Components featured in the following instructions for assembling, operating or maintain

Página 27 - VACUUM SWITCH ADJUSTMENT

Rev 7.0/12-12 4 MT5HV11DC: #35087 ASSEMBLY 1) Open the shipping container and remove all materials for restraining or protecting the vacuum lifter

Página 28 - Adjustment Procedure

Rev 7.0/12-12 5 MT5HV11DC: #35087 equipment design and applicable statutory or regulatory standards must be factored into any specific installation.

Página 29 - REPLACEMENT PARTS LIST

Rev 7.0/12-12 6 MT5HV11DC: #35087 INTENDED USE LOAD CHARACTERISTICS WARNING: This lifter is NOT intended for lifting hazardous materials, such as

Página 30 - LIMITED WARRANTY

Rev 7.0/12-12 7 MT5HV11DC: #35087 OPERATING ENVIRONMENT The operator must determine whether the lifter is intended to be used in each work environme