KEEP FOR FUTURE REFERENCE OPERATING INSTRUCTIONS MODEL NUMBERS: MRT49DC2 MRT4HV11DC2, MRT411LDC2 SERIAL NUMBER: ___________ (please see serial l
Rev 0.5/4-14 8 MRT4-DC2: #35071 Then attach the hoisting equipment hook to the lift bail as shown. Make sure hoisting equipment hook is
Rev 0.5/4-14 9 MRT4-DC2: #35071 5) Connect the electrical connectors as shown. 6) Before you put the lifter into service, perform Operational and
Rev 0.5/4-14 10 MRT4-DC2: #35071 TO CHANGE THE PAD FRAME CONFIGURATION Three pad frame configurations accommodate different load dimensions (see SPE
Rev 0.5/4-14 11 MRT4-DC2: #35071 1 2 3 4 5 6 6 To Install/Remove Extension Arms and Reposition Vacuum Pads 1) Remove the cotterless hitch pin that
Rev 0.5/4-14 12 MRT4-DC2: #35071 To Use Secondary Rotation Stops A second set of rotation stops allows the lift bar to remain perpendicular to the p
Rev 0.5/4-14 13 MRT4-DC2: #35071 INTENDED USE LOAD CHARACTERISTICS This lifter is NOT intended for lifting hazardous materials, such as explosives
Rev 0.5/4-14 14 MRT4-DC2: #35071 OPERATING ENVIRONMENT The operator must determine whether the lifter is intended to be used in each work environmen
Rev 0.5/4-14 15 MRT4-DC2: #35071 OPERATION BEFORE USING THE LIFTER The operator must determine whether the lifter is capable of performing each int
Rev 0.5/4-14 16 MRT4-DC2: #35071 Make sure alarm is clearly audible over ambient noise at operator position. A low vacuum/power loss warning buzzer
Rev 0.5/4-14 17 MRT4-DC2: #35071 Preparing to Use the Optional Remote Control System The optional Remote Control System features a radio receiver,
Rev 0.5/4-14 18 MRT4-DC2: #35071 TO APPLY THE PADS TO A LOAD Positioning the Lifter on the Load 1) Make sure that the contact surfaces of the load
Rev 0.5/4-14 19 MRT4-DC2: #35071 Powering up the Lifter Place the lifter's power switch in the ON ( ) position, as shown (power indicator li
Rev 0.5/4-14 20 MRT4-DC2: #35071 B1 B2 Reading the Vacuum Gauges Two vacuum gauges display the current vacuum level in positive inches of Hg and n
Rev 0.5/4-14 21 MRT4-DC2: #35071 TO LIFT AND MOVE THE LOAD Lift bar must be oriented vertically to lift load (see TO TILT). Interpreting the Warning
Rev 0.5/4-14 22 MRT4-DC2: #35071 Controlling the Lifter and Load When the vacuum indicators show that the lifter is ready, use the hoisting equipmen
Rev 0.5/4-14 23 MRT4-DC2: #35071 B3 TO ROTATE THE LOAD EDGEWISE Never disengage both the rotation latch and the tilt latch at the same time. This
Rev 0.5/4-14 24 MRT4-DC2: #35071 B4 TO TILT THE LOAD Never disengage both the rotation latch and the tilt latch at the same time. This lifter is
Rev 0.5/4-14 25 MRT4-DC2: #35071 TO RELEASE THE PADS FROM THE LOAD Make sure load is fully supported before releasing vacuum pads. 1) Make sure the
Rev 0.5/4-14 26 MRT4-DC2: #35071 AFTER USING THE LIFTER Place the power switch in the OFF ( ) position, as shown (power indicator light turns off
Rev 0.5/4-14 27 MRT4-DC2: #35071 7 5 6 6 8 9 10 11 12 6 4 3 2 1 MAINTENANCE FEATURES 1 POWER SWITCH 2 BATTERY GAU
Rev 0.5/4-14 1 MRT4-DC2: #35071 TABLE OF CONTENTS SPECIFICATIONS ...
Rev 0.5/4-14 28 MRT4-DC2: #35071 MAINTENANCE Make sure battery is disconnected before servicing lifter. Note: Refer to SERVICE MANUAL #36100 when a
Rev 0.5/4-14 29 MRT4-DC2: #35071 Action Every Lift Frequent Periodic Examine the entire lifter for external evidence of looseness, excessive wear, d
Rev 0.5/4-14 30 MRT4-DC2: #35071 3) After the vacuum pump stops running, place the lifter's power switch in the OFF ( ) position. 4) Raise
Rev 0.5/4-14 31 MRT4-DC2: #35071 BATTERY RECHARGE Charge the battery whenever the battery gauge indicates diminished energy (see BATTERY TEST preced
Rev 0.5/4-14 32 MRT4-DC2: #35071 POWER LOSS WARNING BUZZER TEST The power loss warning buzzer is powered by an independent battery, which can be tes
Rev 0.5/4-14 33 MRT4-DC2: #35071 Pad Cleaning 1) Regularly clean the face of each vacuum pad as shown, to remove oil, dust and any other contaminat
Rev 0.5/4-14 34 MRT4-DC2: #35071 REMOTE CONTROL SYSTEM TEST If the lifter is equipped with a Remote Control System, perform this test in the enviro
Rev 0.5/4-14 35 MRT4-DC2: #35071 REPLACEMENT PARTS LIST Stock No. Description Qty. 65211 Check Valve - 1/8 NPT 2 64716 Battery Charger - 0.8 Amp -
Rev 0.5/4-14 36 MRT4-DC2: #35071 LIMITED WARRANTY Powr-Grip products are carefully constructed, thoroughly inspected at various stages of productio
Rev 0.5/4-14 37 MRT4-DC2: #35071
Rev 0.5/4-14 2 MRT4-DC2: #35071 MAINTENANCE FEATURES ... 27
Rev 0.5/4-14 38 MRT4-DC2: #35071
Rev 0.5/4-14 39 MRT4-DC2: #35071
Rev 0.5/4-14 3 MRT4-DC2: #35071 SPECIFICATIONS Description: Designed for use with a crane or other hoisting equipment, MRT4-DC2 lifters employ vacu
Rev 0.5/4-14 4 MRT4-DC2: #35071 SAFETY The following safety rules must be observed to protect the operator and others from potential dangers. Wear
Rev 0.5/4-14 5 MRT4-DC2: #35071 1 13 2 3 4 5 9 8 7 6 11 10 14 12 OPERATING FEATURES Note: Components shown here are underlined on their first appe
Rev 0.5/4-14 6 MRT4-DC2: #35071 13 AIR FILTERS 14 VACUUM GAUGES 15 POWER LOSS WARNING BATTERY 16 VACUUM LIFT LIGHT 17 LOW VACUUM/
Rev 0.5/4-14 7 MRT4-DC2: #35071 ASSEMBLY 1) Open the shipping container and remove all devices for restraining or protecting the vacuum lifter. S